+603 5614 3077 / 3477 / 3577      +603 5614 4277
  contact@3eautomation.com
Home About Us Products Services Stock Updates Contact Us
VLT® Compact Starter MCD 500
VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. AAC...


Power Range
21 – 1600 A, 7,5 – 800 kW
(1,2 MW inside Delta Connection)
Versions for 200 – 690 VAC

AAC, the Adaptive Acceleration Control automatically employs the best starting and stopping profile for the application. Adaptive Acceleration Control means that for each start and stop, the soft starter compares and adapts the process to the chosen profile best suited to the application.

The VLT® Soft Starter MCD 500 has a four-line graphical display and a logic keypad making programming easy. Advanced setup is possible displaying operational status. Three menu systems: Quick Menu, Application Setup and Main Menu provide optimum programming approach.

Protection
As MCD 202 +
Under current
Current imbalance
Starter overtemperature
Restart delay
Warning before trips
Adjustable phase imbalance sensitivity
– Programmable input trip
– Individual phase loss trips
– Individual shorted SCR trips
– Int. bypass relay overload
– Int. bypass relay fail
Fully adjustable protection
Network communication timeout
Heatsink over temperature
Battery/clock failure
Supply frequency External trip
VLT® Compact Starter MCD 200
Due to extensive use of the latest technology, such as new semiconductor control algorithms and bypass design, the new soft starters are very compact and heat dissipation very low...

Product Range
7.5 – 110 kW

Main Features
Current ratings for normal and heavy starting
Versions for 200- 575 V AC
Voltage ramps or current limit ramp soft start
Built-in motor protectionCompact design with internal bypass system for minimum power lossAdd on modules for remote operation and serial communicationSoftware for sizing, control and monitoring.
VLT® Compact Starter MCD 100
MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kW, due to a unique semiconductor design. MCD 100 is a true “fit and forget” product...


Product Range
1.5 kW (MCD 100-001)
7.5 kW (MCD 100-007)
11 kW (MCD 100-011)

All sizes are rated for line voltage up to 600 V AC.

Main Features
MCD 100 products provide timed voltage ramp up and down.
Ramp time can be individually adjusted with rotary switches from 0.4 to 10 seconds.
The start torque can be adjusted from 0 to 85% of the direct on-line torque.
Main Benefits
A robust semiconductor design – selection can be based on motor power which ensures easy selection. Can be used for an almost unlimited number of starts per hour without derating. An universal control voltage
(24-480 V AC / V DC) – simplifies selection and keeps stock at a minimum. A “fit and forget” contactor design – simplifies installation and reduces required panel space. Digitally controlled rotary switches – secure precise settings and simplify installation.
Ratings for heavy duty as standard – simplify selection and reduce the risk of breakdown.